← Lab /Security & privacy

ProvICS dataset enables detection of all 32 attacks with 0.913 F1 and 1.40% false positives

Their ProvICS multimodal provenance dataset allows detection of all labeled attack events with high accuracy

Security & privacy arXiv 7 Jul 2026 Benchmark Prototype evidence Threat model

Published as “ProvICS: A Provenance-based Intrusion Detection for Industrial Control Systems”

Why it matters

The dataset enables evaluation of multimodal intrusion detection methods that require cross-layer visibility, a capability lacking in existing CPS benchmarks.

Summary

ProvICS demonstrates that fusing provenance, Modbus, and physical telemetry detects all 32 labeled attack events (F1 = 0.913, FPR = 1.40%). The dataset comprises a 48-hour benign run and a 22-hour attack run with 32 events covering 20 ATT&CK techniques, collected from a hardware-in-the-loop testbed. Baseline autoencoder detectors show each modality alone misses attacks, but three-modality sum-z fusion achieves 100% recall. The evidence is limited to a single-PLC digital-twin testbed of 70 hours, which the authors note is not large-scale.

What they found 5

  1. Cross-modal fusion detects all 32 attack events with high F1 and low false-positive rate.

    “cross-modal fusion can detect all 32 labeled attack events (F1 = 0.913, false-positive rate (FPR) = 1.40%)”

  2. Provenance-only detection misses 8 attacks, detecting 24 of 32.

    “Provenance only 24 0.7500 0.6818 0.0140”

  3. Physical-only detection misses 15 attacks, detecting 17 of 32.

    “Physical only 17 0.5312 0.6358 0.0140”

  4. Modbus-only detection misses 10 attacks, detecting 22 of 32.

    “Modbus only 22 0.6875 0.7556 0.0140”

  5. Three-modality sum-z fusion achieves 100% recall and F1 0.9133.

    “Sum-z fusion 32 1.0000 0.9133 0.0140”

Caveats 3

  • An OR-calibrated fusion rule reduces FPR to 1.31% but only detects 29 of 32 attacks (quote: "OR-calibrated fusion 29 0.9062 0.8892 0.0131").
  • The current single-PLC, digital-twin testbed is representative rather than large-scale.
  • Although the total collection duration (70 hours) is shorter than some benchmarks (e.g., HAI [8] at 30 days), the per-hour data density is substantially higher.

What’s new here 4

  • Provides synchronized multi-host kernel-level provenance (supervisory host and PLC) together with decoded Modbus and raw PCAP streams.
  • Includes physical process telemetry from a hardware-in-the-loop chemical reactor digital twin.
  • Offers ATT&CK-mapped ground truth across four attack campaigns covering 20 techniques.
  • Publicly released as an open-source multimodal dataset on Hugging Face.

Threat model stated by the source

Adversaryadversary whose objective is to disrupt or destroy the physical process governed by the ICS
Capabilitynetwork-level access, knowledge of standard industrial protocols, multi-stage campaign capabilities spanning reconnaissance, lateral movement, and physical impact