Method maps risk assessment to NAC rules for automotive and energy storage networks
A six-step methodology can translate cybersecurity goals from threat analysis into enforceable network access control rules across domains
Systems arXiv 6 Nov 2026 Method Maturity unclear
Published as “A Cross-Domain TARA-to-NAC Rule Mapping Methodology: From Automotive OEM Networks to Energy Storage Systems”
Why it matters
The methodology offers a reusable pattern for turning risk assessments into enforceable NAC rules across critical infrastructure sectors, but its practical impact remains unproven until empirical deployment and testing are performed.
Summary
The paper presents a six-step manual methodology that translates ISO/SAE 21434 TARA cybersecurity goals into concrete network access control (NAC) rules, binding each rule to IEC 62443-3-3 and ISO/IEC 27001 and applying domain-specific overlays. In an automotive OEM network example, 37 threat entries and 24 goals produce 23 NAC rules covering 11 of the 13 in-scope goals; a battery energy storage system example yields six rules, with three rules having no equivalent in the cited standards. The evidence is limited to desk-based case studies that are not deployed or empirically validated.
What they found 2
- In the automotive example, 37 threat entries and 24 cybersecurity goals yield 23 NAC rules covering 11 of the 13 in-scope goals; the energy example yields six domain rules.
“In the automotive example, 37 threat entries and 24 cybersecurity goals yield 23 network access control rules covering 11 of the 13 in-scope goals; the energy example yields six domain rules.”
- Three of the derived rules have no equivalent in the cited standards.
“Three of the derived rules have no equivalent in the cited standards.”
Caveats 7
- Only 11 of the 13 in-scope automotive goals are covered; two goals (CG-14 and CG-24) remain unmapped.
- The protocol rules only filter on Modbus/DNP3 function codes and do not restrict which registers may be accessed.
- False-telemetry aspects of scenario E4 are not addressed by any rule.
- Both worked examples are desk-based and none of the derived rules is deployed or tested in this paper.
- The energy example is a representative site assembled from public sources rather than a real installation.
- It has no full TARA behind it, its scenarios carry no impact ratings, and its CIP bindings rest on the assumption that the site is categorized medium impact under CIP-002 and has external routable connectivity.
- In the automotive example, 11 of the 24 goals are deferred to future work and two in-scope goals, CG-14 and CG-24, remain unmapped.
What’s new here 4
- Provides a systematic six-step procedure to map TARA goals to NAC rules at named enforcement points, not just to high-level controls.
- Introduces a unified compliance framework that treats IEC 62443 and ISO/IEC 27001 as a fixed substrate with domain-specific standards as interchangeable overlays.
- Demonstrates cross-domain transfer of the methodology from automotive OEM networks to utility-scale battery energy storage systems.
- Identifies rule types (policy-version binding, deny-by-default for undefined roles) that have no direct equivalent in existing standards.