← Lab /AI/ML

Temporal perturbations that mimic sensor bias can drop HAR accuracy up to 40.8 points

Label-free audits using DC-like perturbations can cause large accuracy losses in wearable activity recognizers

AI/ML arXiv 24 Sep 2026 Measurement Prototype evidence

Published as “When Temporal Perturbations Act Like Sensor Biases: Label-Free Auditing of Wearable Activity Recognizers”

Why it matters

The work warns that smooth universal perturbations should not be interpreted as temporal effects without component-level replay, guiding more accurate robustness assessments for wearable HAR systems.

Summary

The paper shows that smooth, phase-robust perturbations applied to wearable HAR models cause large accuracy drops (2.87-40.83 percentage points) and that these drops are usually driven by a persistent DC offset rather than zero-mean temporal variation. Across 27 victim models from three public datasets and three backbone families, the DC component alone accounts for most of the loss (more damaging than AC on 24 of 27 victims and recovers ≥90% of the full drop on 22 of 27), with a held-out UTD-MHAD test confirming a 13.49-pp accuracy loss versus only -0.66 pp for random changes. Evidence comes from a label-sealed audit on subject-disjoint calibration windows, but the study is limited to differentiable, task-trained models and does not assess physical deployment or black-box transfer.

What they found 3

  1. Selected smooth waveforms cause large accuracy losses across victims.

    “selected waveforms cause 2.87-40.83-point three-phase robust accuracy losses.”

  2. The DC offset component is usually more damaging than the AC residual.

    “DC is more damaging than AC on 24/27 victims and recovers at least 90% of the full drop on 22/27; all 5 failures occur on WISDM.”

  3. On a held-out dataset, the selected waveform induces substantial performance degradation compared to random changes.

    “In a held-out UTD-MHAD check, the selected waveform causes 13.49-pp accuracy and 11.68-pp macro-F1 losses, versus -0.66 pp for matched random changes.”

Caveats 4

  • These results do not establish an attack-strength advantage; the mechanism claim is instead tested by post-selection component replay.
  • the paired difference (ours minus UAP-CE) is +0.07 pp (95% setting-cluster bootstrap CI [-0.69, 0.72])
  • Table 1 reports a nine-setting development grid with one fixed victim per dataset-backbone cell; it is not a population estimate.
  • The present protocol targets differentiable, task-trained victims and sample-domain smoothness, while physical sensing, black-box transfer, and foundation-model backbones remain natural next steps.

What’s new here 3

  • Introduces SpectrumAudit, a label-sealed, subject-disjoint audit that selects a smooth waveform without using labels.
  • Proposes a select-then-project test that replays the exact DC component and a budget-constrained zero-mean residual to diagnose whether failures stem from sensor bias or temporal content.
  • Applies the audit across three public wearable datasets and three backbone families, providing systematic component-level analysis of universal perturbations.