← Lab /AI/ML

Cross-encoder bridge shows EEG embeddings leak spectral attributes despite defenses

Frozen EEG foundation-model embeddings retain leakable spectral attributes that transfer across encoders via a ridge decoder

AI/ML arXiv 8 Jun 2026 Measurement Prototype evidence

Published as “Pretrained, Frozen, Still Leaking: Auditing Cross-Encoder Attribute Transfer in EEG Foundation Models”

Why it matters

Deployers of EEG foundation-model embeddings should treat them as non-private for spectral attributes, even when standard single-endpoint audits suggest safety.

Summary

A cross-encoder transfer audit shows that a ridge attribute decoder trained on one frozen EEG foundation model transfers, via a linear bridge, to every other model and leaks spectral attributes even though raw-waveform reconstruction, membership inference, and reference-set identity audits all pass. The paper reports a 95% CI lower bound of at least 0.081 on held-out-subject attribute gain across all six BIOT/LaBraM/EEGPT directions and positive audit-endpoint disagreement scores (AEDS) in all eight cells (p < 0.001). The evidence comes from multiple datasets (EEGMMI, Sleep-EDF, LIMO, CHB-MIT) and several decoders, but the results are limited to the tested models and splits and are not population-level guarantees.

What they found 2

  1. Cross-encoder transfer leaks spectral attributes across all model pairs

    “the bridged decoder produces a held-out-subject centered PSD gain that exceeds the stronger same-seed matched negative control with 95% CI lower bound at least 0.081 and mean gain at least 0.244 (Table 7).”

  2. Subject-disjoint attribute leakage remains positive in all evaluated settings

    “Across eight evaluation settings, every subject-disjoint 95% interval remains above zero against the stronger sameseed random/split-permuted negative control and against target permutation.”

Caveats 5

  • Per-cell LiRA membership AUC ranges from 0.498 to 0.695, well below what would be needed to close the attribute gap, indicating that membership inference remains weak despite strong attribute leakage.
  • These intervals are descriptive finite-split audit summaries; they are not population-level guarantees over all subjects, devices, or EEG datasets.
  • We do not estimate the theorem’s projector overlap; the theorem fixes the mechanism that the empirical transfer test probes.
  • We do not promote this consistency check into a parameter estimate of β for any specific encoder pair.
  • We do not estimate the theorem’s subspace or margin parameters for BIOT, LaBraM, or EEGPT, so the theorem should not be read as a quantitative model of these curves.

What’s new here 3

  • Demonstrates that attribute leakage can be detected via cross-encoder transfer, a joint audit that single-endpoint tests miss.
  • Introduces a bridge-theorem providing sufficient conditions for transferability and an audit-endpoint disagreement score (AEDS) for deployment decisions.
  • Shows that standard defenses (Gaussian noise, bottleneck, dropout, DP-SGD) fail to close the attribute channel while preserving utility.