← Lab /Security & privacy

Laser fault injection bypasses Ed25519 verification on TROPIC01, enabling firmware control

A single laser pulse can reliably cause an invalid Ed25519 signature to be accepted by the TROPIC01, granting arbitrary firmware execution.

Security & privacy Ledger Donjon 3 Jun 2026 Attack Real-world evidence

Published as “Laser Fault Injection on the TROPIC01 Open-Source Secure Element”

Why it matters

Bypassing signature verification on a secure element demonstrates that even open-source hardware can be vulnerable to physical attacks, highlighting the need for robust fault-injection countermeasures.

Summary

The researchers used a 1064 nm laser to inject faults into the SPECT coprocessor of the TROPIC01 during the final comparison of Ed25519 verification. A single precisely timed pulse caused an invalid signature to be accepted, allowing them to load modified firmware via the update protocol. They then repeated the fault at boot to bypass the CPU firmware signature, achieving arbitrary firmware execution. The attack works on samples with laser detectors enabled, though mitigation raises the required fault count and reduces success speed.

What they found 2

  1. A single laser pulse timed to the final comparison can make an invalid Ed25519 signature be accepted.

    “It worked. By firing a pulse at the right time and position, we were able to make an invalid signature pass as valid.”

  2. The complete attack requires two independent laser faults (update and boot).

    “The complete attack therefore requires two sequential (but otherwise independent) faults:”

Caveats 5

  • The authors were unable to recover secrets from the MACANDD block despite systematic fault attempts.
  • The attack requires precise timing and spatial targeting of the SPECT logic, which may be difficult without detailed die knowledge.
  • Without dynamic synchronization on the power consumption traces, performing both faults takes about one hour on average.
  • Mitigation by disabling MAINTENANCE mode forces the attacker to perform two faults instead of one, reducing the overall success rate.
  • The first fault was easier and faster to reproduce than expected, with a success rate close to 90% and many retry opportunities per second.

What’s new here 4

  • Demonstrates that a single laser pulse can flip the result of Ed25519 verification on an open-source secure element.
  • Shows that the vulnerability persists even when laser detection circuitry is enabled.
  • Provides a full end-to-end attack chain: fault during update and fault during boot to achieve arbitrary firmware execution.
  • Analyzes mitigation by disabling MAINTENANCE mode and quantifies its impact on attack complexity.