← Lab /AI/ML

Only 31% of LLM-agent PLC attacks achieve sustained physical impact

Autonomous LLM agents can sustain adverse physical impact on PLCs in about one-third of attempts

AI/ML arXiv 27 Aug 2026 Measurement Prototype evidence

Published as “PLCBench: Can Autonomous LLM Agents Turn PLC Access into Sustained Physical Impact?”

Why it matters

Defenses need to focus on the cyber-to-physical transition (e.g., limiting engineering-service reachability and process-relevant writes) rather than relying on protocol friction as a durable security boundary.

Summary

Autonomous LLM agents can achieve sustained physical impact on real PLCs, but only in 75 of 240 episodes (31.3%). The study runs a hardware-in-the-loop benchmark across four commercial PLCs, four closed-loop processes, and five LLM families, measuring six diagnostic flags to locate failure points. Evidence is based on 240 real-PLC episodes (118 PLC-hours) with deterministic evaluation, showing early barriers in interface acquisition and limited repeatability across configurations.

What they found 3

  1. Overall sustained impact rate is 31.3% (75/240 episodes).

    “Across five LLM families and 240 real-PLC episodes, 75 episodes (31.3%) sustain their respective physical objectives.”

  2. Native-interface acquisition is the first major barrier, causing 98 early stops.

    “Native-interface acquisition accounts for 98 early stops.”

  3. Richer process observation raises conditional post-write impact from 44.2% to 64.0%.

    “Conditional impact after manipulate increases from 38 of 86 episodes (44.2%) to 57 of 89 (64.0%).”

Caveats 5

  • Only 31.3% of episodes achieve sustained impact, indicating limited overall success.
  • Early barriers cause 98 episodes to stop before acquiring a usable PLC interface.
  • Repeatability is uneven: only 12 of 80 PLC-workload cells succeed in all three repetitions.
  • Protocol complexity, undocumented object semantics, and scarce target-specific knowledge can slow an agent’s exploration, but they do not prevent impact once the missing knowledge can be reconstructed online.
  • The evaluation shows that current agents can complete end-to-end cyber-to-physical attacks in validated laboratory HIL settings, but reliability is uneven.

What’s new here 3

  • First real-PLC hardware-in-the-loop framework (PLCBENCH) that combines vendor-native interaction, commercial PLC execution, and closed-loop process simulation.
  • Six hidden diagnostic flags that localize failure stages from interface discovery to sustained physical impact.
  • Systematic evaluation of multiple LLM families across heterogeneous PLCs and workloads, quantifying the effect of richer process observation on success rates.