Smart home system cuts energy use by over 46% in two-room test

The proposed IoT automation system reduces household energy consumption by more than 46% compared to an always-on setup

Security & privacy arXiv 20 May 2026 Method Prototype evidence

Published as “An IoT-Enabled Smart Home Automation System for Energy Efficiency with Web-Based Control”

Why it matters

A 46% energy reduction demonstrates that inexpensive, sensor-driven automation can meaningfully lower household power use, but deployment must address hardware robustness and security before real-world adoption.

Summary

The prototype smart-home system cut total energy use by 46.5% compared with an always-on baseline, saving £0.224 over a 12-hour test. It achieved this with motion-gated LED lighting and PWM-controlled fan speeds, and the dashboard responded to sensor events within 1-2 seconds. The evidence comes from a single 12-hour laboratory experiment on two breadboard-wired rooms, so the result is promising but limited in scale and realism.

What they found 3

  1. Energy consumption was reduced by 46.5% compared with an always-on configuration.

    “The smart system reduced energy consumption by approximately 46.5%, validating the effectiveness of motion gating and PWM scaling.”

  2. Actuator response time after sensor trigger was 1-2 seconds.

    “Response time from the sensor triggers to the responses of the actuators was 1-2 seconds.”

  3. The system remained stable for a continuous 12-hour run.

    “System Uptime 12 hours (stable)”

Caveats 5

  • The paper notes that security features were limited to a simple login/logout mechanism, exposing the system to brute-force and session-hijacking attacks.
  • The web interface lacks transport-layer encryption, and CSV logs are not integrity-protected, undermining the claim of a robust, secure deployment.
  • Limitations include reliance on breadboard wiring, which is impractical for permanent use, and the slight lag on the dashboard when CPU usage is high.
  • The security features were limited and only included simple login/logout.
  • No security measures were implemented to secure the data - they were just plain csv files with no security whatsoever.

What’s new here 4

  • Low-cost modular implementation using a Raspberry Pi 5 and off-the-shelf sensors.
  • Automatic control via motion-gating and PWM scaling of LEDs and fans.
  • Web-based Flask dashboard providing real-time monitoring, manual override, and CSV logging.
  • Quantitative evaluation showing a 46.5% reduction in energy consumption over a 12-hour test.