← Lab /Systems

Contactless EMI can spoof tactile sensors causing unsafe robot behavior

GhostTac can manipulate tactile sensor outputs via electromagnetic interference to induce harmful robot actions

Systems arXiv 21 Aug 2026 Attack Prototype evidence

Published as “GhostTac: Manipulating Tactile Sensors without Physical Contact”

Why it matters

Contactless EMI can cause robots to apply unsafe forces or lose tactile feedback, potentially damaging equipment or injuring humans in medical and domestic settings.

Summary

GhostTac can remotely manipulate tactile sensor readings and induce denial-of-service conditions using crafted electromagnetic interference, achieving 100% success in force magnitude, location, and pattern control across 15 commercial sensors and two dexterous hands, and causing up to 4870 g spurious weight readings. The attack also works at distances up to 3 m and through walls, windows, and doors. Evidence comes from laboratory experiments on real hardware, including three task-level case studies (grasping, slip detection, material classification).

What they found 3

  1. All tested sensors could be manipulated for positive or negative deviations, and 13 of 15 were vulnerable to DoS attacks.

    “The results demonstrate that all tested sensors could be successfully manipulated to exhibit positive or negative measurement deviations, and 13 out of 15 were susceptible to DoS attacks.”

  2. Injecting a 1156 MHz signal into the RPPS-36 array produced a spurious weight of 4870 g on a single unit and a mean induced weight of 4812 g across the array.

    “For example, when injecting a 1156 MHz signal into the RPPS-36 array, the most affected sensing unit reported a spurious weight of 4870 g, with a mean induced weight of 4812 g across all units.”

  3. GhostTac achieved bottle-squeezing attacks at distances up to 3 m.

    “GhostTac achieved bottle-squeezing attacks at distances up to 3 m, as shown in Fig. 21.”

Caveats 3

  • HangKai Fingertip ... 7/10
  • Isense UM1208 ... 6/10
  • Linker L10 Tip ... ×

What’s new here 4

  • First contactless EMI attack targeting tactile sensors.
  • Fine-grained control over force magnitude, spatial location, interference width, and dynamic patterns.
  • Demonstrated long-range (up to 3 m) and through-obstacle attacks.
  • Comprehensive evaluation on 15 sensors from 8 manufacturers and two dexterous hands.