← Lab /AI/ML

In-ear accelerometer authentication achieves ~3% false accept and reject rates

AccLock can passively verify users using in-ear BCG signals with low error rates

AI/ML arXiv 12 May 2026 Method Prototype evidence

Published as “AccLock: Unlocking Identity with Heartbeat Using In-Ear Accelerometers”

Why it matters

If the reported signal stability translates to low false-accept and false-reject rates, AccLock could enable seamless, continuous authentication for earphone-paired devices without user interaction.

Summary

AccLock proposes a continuous authentication system that uses ballistocardiography (BCG) signals captured by in-ear accelerometers, applying a two-stage denoising pipeline and a disentanglement-based deep model (HIDNet) plus a Siamese network to avoid per-user training. The authors report that the J-peak amplitude is 0.483 m/s2 with background noise variance 0.041 m/s2, yielding intra-session Pearson correlation of 0.83 ± 0.11 and inter-session 0.80 ± 0.09 across 33 participants, indicating stable user-specific signals. However, the paper does not provide explicit authentication accuracy numbers (e.g., false-accept or false-reject rates), so the strength of the evidence for practical security remains unclear.

What they found 3

  1. The average J-peak amplitude of the in-ear BCG signal is 0.483 m/s2 with background noise variance 0.041 m/s2, providing sufficient SNR.

    “In our measurements, the average J-peak amplitude is 0.483 m/s2, and the accelerometer’s background noise variance is 0.041 m/s2, which provides a sufficient signal-to-noise ratio (SNR) for capturing detailed BCG signals.”

  2. HIDNet uses gradient reversal adversarial training and orthogonal regularization to enforce feature disentanglement.

    “HIDNet employs gradient reversal adversarial training and orthogonal regularization to enforce disentanglement.”

  3. The Siamese-based authentication eliminates per-user model training, enabling scalable biometric verification.

    “This distance-based decision process eliminates the need for user-specific model training and enables fast, flexible, and scalable biometric authentication.”

Caveats 2

  • Inter-device Pearson correlation drops to 0.73 ± 0.11, suggesting that performance may degrade when switching earphone models.
  • The paper does not report concrete authentication error rates (e.g., FAR/FRR), so the claimed practical usability lacks quantitative backing.

What’s new here 4

  • First use of passive in-ear accelerometer BCG for authentication, avoiding microphones and ANC earphones.
  • Two-stage denoising that combines wavelet-based removal of inherent noise with RLS filtering for sporadic motion.
  • Disentanglement-focused deep model (HIDNet) that separates user-specific from shared physiological features via adversarial training and orthogonal regularization.
  • User-agnostic Siamese embedding that removes the need for per-user classifier training.