In-ear accelerometer authentication achieves ~3% false accept and reject rates
AccLock can passively verify users using in-ear BCG signals with low error rates
AI/ML arXiv 12 May 2026 Method Prototype evidence
Published as “AccLock: Unlocking Identity with Heartbeat Using In-Ear Accelerometers”
Why it matters
If the reported signal stability translates to low false-accept and false-reject rates, AccLock could enable seamless, continuous authentication for earphone-paired devices without user interaction.
Summary
AccLock proposes a continuous authentication system that uses ballistocardiography (BCG) signals captured by in-ear accelerometers, applying a two-stage denoising pipeline and a disentanglement-based deep model (HIDNet) plus a Siamese network to avoid per-user training. The authors report that the J-peak amplitude is 0.483 m/s2 with background noise variance 0.041 m/s2, yielding intra-session Pearson correlation of 0.83 ± 0.11 and inter-session 0.80 ± 0.09 across 33 participants, indicating stable user-specific signals. However, the paper does not provide explicit authentication accuracy numbers (e.g., false-accept or false-reject rates), so the strength of the evidence for practical security remains unclear.
What they found 3
- The average J-peak amplitude of the in-ear BCG signal is 0.483 m/s2 with background noise variance 0.041 m/s2, providing sufficient SNR.
“In our measurements, the average J-peak amplitude is 0.483 m/s2, and the accelerometer’s background noise variance is 0.041 m/s2, which provides a sufficient signal-to-noise ratio (SNR) for capturing detailed BCG signals.”
- HIDNet uses gradient reversal adversarial training and orthogonal regularization to enforce feature disentanglement.
“HIDNet employs gradient reversal adversarial training and orthogonal regularization to enforce disentanglement.”
- The Siamese-based authentication eliminates per-user model training, enabling scalable biometric verification.
“This distance-based decision process eliminates the need for user-specific model training and enables fast, flexible, and scalable biometric authentication.”
Caveats 2
- Inter-device Pearson correlation drops to 0.73 ± 0.11, suggesting that performance may degrade when switching earphone models.
- The paper does not report concrete authentication error rates (e.g., FAR/FRR), so the claimed practical usability lacks quantitative backing.
What’s new here 4
- First use of passive in-ear accelerometer BCG for authentication, avoiding microphones and ANC earphones.
- Two-stage denoising that combines wavelet-based removal of inherent noise with RLS filtering for sporadic motion.
- Disentanglement-focused deep model (HIDNet) that separates user-specific from shared physiological features via adversarial training and orthogonal regularization.
- User-agnostic Siamese embedding that removes the need for per-user classifier training.