← Lab /Systems

Malicious node can fully desynchronize network-agnostic guardian causing undetected message collisions

A timing attack can cause 100% successful undetected collisions of critical messages by exploiting clock sync limits

Systems arXiv 26 Jun 2026 Attack Simulation evidence Threat model

Published as “Exploring and Exploiting Synchrony Limitations of Time-Triggered Network-Agnostic Guardians”

Why it matters

Network-agnostic guardians, despite their low cost, are vulnerable to timing attacks that can silently corrupt safety-critical messages, indicating a need for additional protection such as proactive node rejuvenation.

Summary

The paper demonstrates a timing attack that fully desynchronizes a network-agnostic guardian, causing collisions with a targeted critical message with 100% success while remaining undetected. The attack exploits the unavoidable imprecision in node-guardian clock synchronization, injecting covert delays up to the theoretical bound. Results are obtained from an eight-node FlexRay simulation (500 runs per configuration), showing the attack works for every victim slot. The authors note the evaluation is limited to simulation and assumes best-case synchronization precision.

What they found 1

  1. The attack remains undetected and disrupts the target message with 100% success.

    “Our results show that the attack is able to remain undetected with 100% success and disrupts the transmission of the critical messages of the target node by causing collisions with them with 100% success.”

Caveats 4

  • However, an attacker may inject a delay larger than the maximum covert value and still remain undetected. For clock deviation between the node and the guardian smaller than Γ, TINJ values exceeding the theoretical maximum can still result in a CS signal that passes the acceptance window check, since Eq. 4, being pessimistic, assumes the maximum possible clock drift between the node and the guardian.
  • The chosen clock-synchronization precision between a node and its network-agnostic guardian does not prevent targeted-slot attacks, as demonstrated by the theoretical result in Section IV.
  • We suspect that proactive rejuvenation alone may suffice for certain system configurations, depending on the structure of the communication schedule, the clock synchronization protocol, and the time required to compromise a node.
  • Since communication between guardians is costly, we will explore, in future work, the interplay between enforcing proactive node rejuvenation by network-agnostic guardians and the necessity for explicit communication among guardians.

What’s new here 4

  • Derives a theoretical lower bound on the precision of external clock synchronization between a node and its network-agnostic guardian.
  • Designs a timing attack that injects covert delays to shift the guardian’s view of global time and cause slot collisions.
  • Provides a formula for the maximum covertly injectable delay (TINJ = πNG - 2ρRint).
  • Validates the attack in OMNeT++/FiCo4OMNeT FlexRay simulations, achieving 100% undetected success across all target slots.

Threat model stated by the source

Adversarymalicious node that the attacker fully controls
Capabilitycan send arbitrary messages, manipulate clock synchronization signals, and knows schedule and timing parameters
Assumesattacker can infer timing information about the system; guardians perform only acceptance window check on CS signal